Converting thermocouple voltages to temperature.

·4 mins
Background # Unlike most sensors used in data acquisition, thermocouples do not have a linear mapping between their voltage and celcius values. This means that instead of factoring some scalar value against the data, in order to scale it to engineering units (eg. volts to acceleration), an experimentally derived equation must be created to approximate the temperature at specific voltages. This non-linearity is primarily due to the materials being used to discover the temperature difference.

Writing a TEDS (IEEE 1451.4) parser.

·3 mins
I was tasked recently with writing a parser for TEDS bit stream data. There is an IEEE published paper with an overview of the standard but it doesn't give any examples for implementation. I was finally able to find a paper that gave examples but still had trouble parsing the data. I finally realized there is not only 2 selector bits after the basic TEDS block but selector bits inside the standard template (2 in the case of template 25). Here are my main findings: \